MIL-PRF-24021K
4.4.1 Functional inspections.
4.4.1.1 Input power to AC monitors. The AC monitor shall be tested using an AC power
source having the characteristics specified in 3.4.1.1. The AC monitor shall not be damaged and
shall not reset automatically when the input power conditions specified in 3.4.1.1 are applied to the
monitor.
4.4.1.2 Input power to power lead (pin G) and sense lead (pin B). The DC monitor shall be
tested using a DC power source having the characteristics specified in 3.4.2.1. The DC monitor
shall not be damaged and shall not reset automatically when the input power conditions specified in
3.4.2.1 are applied to the monitor.
4.4.1.3 Inhibit voltage at pins C and E test. The DC monitor shall be tested during application
of an inhibit voltage having the characteristics specified in 3.4.2.2. The performance specified in
3.4.2.2 shall be met.
4.4.1.4 AC monitor including source of DC for contactor test. The specified output current
capacity of the M24021-3 monitor shall be tested by applying loads to the monitor corresponding to
the currents and time duration specified in 3.4.3.1. The performance specified in 3.4.3.1 shall be
met.
4.4.1.5 AC monitors excluding power supply test. The specified output current capacity of the
M24021-5 monitor shall be tested by applying loads to the monitor corresponding to the currents
and time duration specified in 3.4.3.2. The performance specified in 3.4.3.2 shall be met.
4.4.1.6 Current capacity of DC monitors. The specified output current capacity of the
M24021-6 monitor shall be tested by applying loads to the monitor corresponding to the currents
and time duration specified in 3.4.3.3. The performance specified in 3.4.3.3 shall be met.
4.4.1.7 Operation of AC monitors test. Operation of the AC monitors shall be tested in
accordance with and meet the requirements of 3.4.4.1.
4.4.1.8 Operation of DC monitors test. Operation of the DC monitors shall be tested in
accordance with and meet the requirements of 3.4.4.2.
4.4.2 General environmental service conditions. After subjected to the environmental test
requirements of MIL-E-81910, the external power monitor shall meet the requirements of 3.4
where applicable.
4.4.2.1 Sand and dust test. After subjected to the dust test of MIL-E-81910, the external
power monitor shall meet the requirements of 3.4.